15 Series Photo Ionizer

VSH-15G/VSC-15G

A high-performance photo ionizer
using a
CNT X-ray tube (world's first)
and capable of
high output and
a high degree of speed control.

A photo ionizer equipped with a CNT X-ray tube (world's first),
it is capable of high
output and a high degree of speed control.
It is suitable when a high static elimination
capacity is required in a large area.
In addition, it allows the operator
to connect it with a
PC to identify ON/OFF, operation time of tube, failure, etc.

※ Be sure to install the head in a shielded facility.

Features

  • Head
    • Equipped with CNT X-ray tube for high output and high speed control
    • It can remove static electricity from distant objects over a large area
  • Controller
    • Displays operation hours of the head
    • Can be connected to external devices using RS-485 communication (Remote Control)
    • Up to 4 head units can be connected
  • Perfect ion balance
  • Free of foreign substances
  • Maintenance free
  • Fast static elimination
  • Ozone free

Application

  • Semiconductors When processing wafers and dies
  • Film Separation/Wounding/
    Transfer section
  • Display Return (transfer) section
  • Plastic Injection/Parts/Materials Feeding
  • Pharmaceutical powder packing 
  • Inside the facility Rubbing machine, exposure machine, etc.

Specification

VSH-15G / VSC-15G Product Specifications

Product Item Content
Common Operating temperature 0~40℃
Storage temperature -10℃~60℃
Operating humidity Within 60%
Storage humidity Within 85%
HEAD
(VSH-15G)
Tube voltage (DC) 15 kV
Angle of irradiation 150º
Power input DC +24 V
MAX power consumption 38 W
Weight 0.4 kg
CONTROLLER
(VSC-15G)
Power input AC 100~240 V, 50/60 Hz
MAX power consumption 70 W
Weight 0.65 kg
I/O Interface Remote, Interlock, Fail
Communications RS-485
I/O Pin Connector DSUB25P Female
* Design and product specifications are subject to change without notice for quality improvement.

Decay Time Rate

* Static electricity elimination performance is indicated by the time it takes for a metal plate charged at ±1000 V to drop to ±100 V after being irradiated with Soft X-Ray.

Shielding Methods

Material Shielding thickness (mm)
Stainless steel 0.5
Aluminum 9
Glass 17
PVC 14
Acrylic 148
* The above shield thickness is based on when the shield is 10 cm away from the radiation source. If the shield is closer to the radiation source, its thickness must be increased.
* After shielding, the measured external radiation dose must be within the legal limit (10 μSv/h).

Dimensions(mm)

  • Head (VSH-15G)

  • Controller (VSC-15G)

Components

Components

  • Head (VSH-15G) / max. 1ea
  • Controller (VSC-15G) / 1ea
  • Output Cable (20m) / 1ea
  • D-Sub Signal Cable 25pin
    (5m) / 1ea
    Part #: D-15P-0005
  • Fixing Bolt
    M4 X 0.7pitch X 10L / max. 8ea
  • Power Cable (1.8m) / 1ea

Download
Catalogs and manuals are available.